LogoLogo
  • LIBSAFE Advanced Pro - System Administrator Manual
  • Introduction
    • Basic concepts
    • General considerations
  • System configuration
    • Storage
      • Storage groups
      • Disks
        • Different storage system types and their integration in LIBSAFE
      • Datamover
    • Digital signature profiles
      • Certificates for the digital signature service
    • Access
      • Users
        • Two-Factor Authentication (2FA)
      • Groups
      • User permissions
    • Alarms and Notifications
      • Alarm definition
      • Configured alarms
        • Configuring an alarm: example 1
        • Configuring an alarm: example 2
      • Notifications panel
    • Extras and tools
      • Programmed tasks
      • Logs manager
      • File management
      • Database management
      • Database management (read-only mode)
      • Web interface configuration variables
      • Configuration variables
      • API system services
      • Server cluster - Parallelization
        • Details of activity in one node
        • Editing or creating a node and its associated services
        • Node deactivation
        • Deleting nodes
        • Processing Cluster customization
      • SAML integration as a SSO (Single Sign On) when login in LIBSAFE
    • License
  • Preservation configuration
    • Ingestion sanitizers
      • Ingestion sanitizers detail
      • Ingestion sanitizer editing
    • Preprocessors
      • Preprocessor details
      • Creation of the preprocessor
      • Preprocessor editing
    • Ingestion checks
      • Ingestion check details
      • Creation of the ingestion check
      • Ingestion check editing
      • Main ingestion checks
    • Metadata filters
      • Metadata filter detail
      • Creation of metadata filter
      • Metadata filter editing
    • Dissemination Information Package (DIP) profiles
      • DIP profile detail
      • Creation of DIP profiles
      • DIP profile edition
    • Connectors
      • Connector Detail
      • Create a new connector
      • Edit a connector
    • File formats
      • File format detail
    • File format characterizers
      • File format characterizer detail
    • File format validators
      • File format validator detail
    • File format evolvers
      • File format evolver detail
  • Frequently Asked Questions (FAQ) and additional notes
Powered by GitBook
On this page

Was this helpful?

  1. Preservation configuration
  2. Ingestion sanitizers

Ingestion sanitizer editing

PreviousIngestion sanitizers detailNextPreprocessors

Last updated 3 years ago

Was this helpful?

The basic parameters common to all the sanitizers can be configured in the sanitizer configuration screen: from the name or description of the sanitizer to its state or the maximum number of instances allowed in each preservation plan.

It is also possible to configure the ingestion sanitizer parameter. If it does not exist, clicking on Add will open the form to create the new sanitizer parameter. If the parameter already exists, it can be edited or deleted. In case of editing, a form will open in order to modify the following points:

  • Description: a brief description of the parameter, syntax, possible values, etc.

  • Type of parameter: as explained earlier, the value of the parameter introduced in the creation of a preservation plan will be validated when associated to a preprocessor. Besides, if the type of data selected is numeric, the value of the parameter can be assigned to a range and that range can be specified.

  • Recommended value: we can indicate a value to facilitate the configuration of the preprocessor later on. This value will be modifiable when we apply a preprocessor in a preservation plan.

  • Default value: in a situation where the preprocessor will always need to have a value for the parameter, but where there may be cases in which due to either the preprocessor or because the user should not be forced to introduce the value, this field can be filled out with the value to be applied by leaving the parameter value blank when configuring a preprocessor in a preservation plan.

  • Mandatory: it is a check that indicates whether it is mandatory to put a value on the parameter of the preprocessor, or not.

Note: ingestion sanitizers can only admit the configuration of one parameter.